Getinge Maquet Servo-i Features
The Getinge Maquet Servo-i ventilation system can be used on a variety of patients from neonatal, pediatric, and adults. It has the ability to handle the most acute phases of respiratory distress, through recovery, and to the waning phases of the ventilation process. The Servo-i continuously delivers outstanding ventilator treatment as gently as possible. This is in part due to the performance, monitoring capabilities, treatment options, and tools that this ventilator offers. Since this ventilator can be used on a wide variety of patients, it is suitable for most environments from the ICU to the NICU department. The Maquet Servo-i ventilator allows you to choose the treatment option based on your patients’ needs without having to worry about the ventilator’s capabilities.
Servo-i supports both invasive and non-invasive ventilation. It combines the highest level of clinical performance with outstanding mobility and cost-efficiency. Ease of training, operation, and maintenance, as well as flexibility and modularity, ensures a low life-cycle cost. The economic benefits of operating this modular platform are considerable: there is no need to scrap and reinvest for different patient categories and situations.
The Servo I ventilator is easy to use and learn about. The ventilation system provides the information you need, when you need it, allowing a fast and appropriate response from the user. The user-friendly interface gives easy access to all settings and even reaches the most important parameters through direct access knobs. This way, the clinician is always informed, in control, and able to react.
The Servo-i ventilation system is an all-in-one platform with advanced features you would normally expect from an advanced system. In patients with ALI and ARDS, it is difficult to identify harmful ventilator patterns, most importantly Barotrauma. The adult and universal Servo-i configurations have a feature called Stress Index that helps clinicians detect and prevent potentially high-risk scenarios in adults. The ventilator analyzes changes in the compliance of the respiratory system during the constant flow of controlled breaths. This unit also has a Heliox option which is a low-density gas mixture of helium and oxygen. Heliox is widely recognized as a therapy that minimizes turbulence and improves CO2 elimination.
This ventilator is designed to meet your clinical needs. It’s a single system that offers a broad range of treatment options, which means it is always ready to adapt to your changing medical needs. This ventilator comes in 3 different configurations; infant, adult, and universal. The infant configuration doesn’t have the Stress Index and the Hyperbaric Oxygen Therapy (HBO) feature. The Adult configuration doesn’t have the Nasal CPAP or the HBO feature. If you are interested in knowing exactly what features each configuration has, call 1-800-GET-SOMA and one of our knowledgeable sales representatives will assist you.
Maquet Servo-i Specifications
Dimensions
- Height: 51.8 In (131.5 cm)
- Width: 22 In (56 cm)
- Depth: 25.2 In (64 cm)
- Weight: 44.1 lbs (20 kg)
General
- Method of triggering: Flow, pressure, and Edi (optional)
- Max. operating pressure: Approximately 115 cmH2O
- Bias flow: 2 l/min
Inspiratory Channel
- Pressure drop: Max. 6 cmH2O at a flow of 1 l/s
- Internal compressible factor: Max. 0.1 ml/cmH2O
- Gas delivery system: Microprocessor-controlled valve
- Inspiratory flow range:
- Adult: 0 to 3.3 l/s
- Infant: 0 to 0.55 l/s
Expiratory Channel
- Pressure drop: Max. 3 cmH2O at a flow of 1 l/s
- Internal compressible factor: Max. 0.1 ml/cmH2O
- PEEP regulation: Microprocessor-controlled valve
- Rise Time, Expiratory Flow Measurement: <12 ms for 10 – 90 % response at the flow of 0.05 – 3.2 l/s
- Expiratory flow range: 0 to 3.2 l/s
Screen
- Type: TFT-LCD module
- Size: 31 cm (12.1”) diagonal
- Viewing area: 246.0 x 184.5 mm
Operating Conditions
- Operating temperature: +10 to +40ºC
- Relative humidity: 15 to 95% non-condensing
- Atmospheric pressure: 660 to 1060 hPa
- The lowest pressure in breathing system: –400 cmH2O
Power Supply
- Power supply, automatic range selection
- 100 – 120 V AC ±10%
- 50 – 60 Hz
- 220 – 240 V AC ±10%
- 50 – 60 Hz
- Plug-in battery module
- Battery backup: Two battery modules are delivered with the ventilator.
- 50 – 60 Hz
- 220 – 240 V AC ±10%
- 50 – 60 Hz
- Battery capacity: Rechargeable, 12 V, 3.5 Ah each
- Recharge time: Approximately 3 h/battery
- Battery backup time: At least 3 h, when using six batteries.
- External 12 V DC: 12.0 V – 15.0 V DC, 10 A
- Max power consumption
- At 100 – 120 V: 2 A, 190 VA, 140 W
- At 220 – 240 V: 1 A, 190 VA, 140 W
Invasive Ventilation
-
Inspiratory tidal volume
- Adult 100–4000 ml
- Infant 2–350 ml
- Inspiratory flow =200 l/min
- PEEP 0–50 cmH2O
-
Pressure above PEEP
- Adult 0– (120-PEEP) cmH2O
- Infant 0 –(80-PEEP) cmH2 O
Non-Invasive Ventilation
- PEEP 2–20 cmH2O
- Pressure above PEEP 0– (62-PEEP) cmH2 O
-
Leakage compensation
-
Adult
- Inspiratory, up to 200 l/min
- Expiratory, up to 65 l/min
-
Infant
- Inspiratory, up to 33 l/min
- Expiratory, up to 25 l/min
- Nasal CPAP, up to 20 l/min
Connectivity
- External device interfaces 2xRS232, remote alarm, MCare remote service
- IHE technical framework MSync HL7 converter
Refurbished Getinge Servo-i Ventilator
Soma Tech Intl offers the Getinge Servo-i ventilator at prices up to 50% below OEM rates, providing the same service and warranty as a new unit. This Maquet ventilator undergoes both technical and cosmetic reconditioning to ensure it functions and appears as if it were new. During the refurbishment of the Servo-i, our in-house biomedical engineers, who are highly skilled and certified to work on ventilators, meticulously inspect and test the unit. If necessary, components are replaced to ensure that all aspects of the Maquet Servo-i ventilator meet the original manufacturer’s engineering specifications. This guarantees that the device operates just as it did when it initially left the manufacturer.
Once the Servo-i ventilator is fully operational, it undergoes a detailed cosmetic restoration process. The Maquet Servo ventilator is thoroughly cleaned, minor scratches and dents are repaired, it is repainted, and new decals are applied if necessary. After this rigorous reconditioning process, the device both functions and looks like new. Soma Tech Intl is ISO 13485 certified, ensuring that the highest quality standards are upheld for all capital medical equipment sold. Before the Getinge Servo-i ventilator is labeled as patient-ready and prepared for shipment, it undergoes a final quality control test to confirm that all aspects are functioning as they should.
Soma Tech Intl is actively seeking to purchase Getinge Servo-i ventilators. If you or your facility are looking to sell your Servo-i or any Maquet ventilators, be sure to contact Soma Tech Intl. Soma has a dedicated and experienced purchasing department that will guide you through the entire process. Selling your used or pre-owned Getinge ventilators directly to Soma eliminates the middleman, ensuring your medical facility receives the highest value for your equipment. Soma is 100% HIPAA compliant, ensuring your equipment arrives at our facility in the same condition it left yours. Soma Tech Intl also offers trade-in credit for your medical equipment. If you have a Servo-i ventilator or other Maquet Servo ventilators you would like to sell, send us a message.